• Delivery RET-3000in stock
  • Warranty 5 years
  • Price on-demand

RET-3000

Loading transformer, serves for increasing the output current up to 3500 A

Having considered the previous experience with RETOM-11 and our customers' wishes we at Dynamics Ltd designed a loading transformer RET-3000. This transformer gives the maximally possible current with the maximally possible readings.

The loading transformer RET-3000 works together with RETOM-11M and serves for increasing the output current up to 3500 A. Therefore it is a necessary element of the testing system RETOM-11M if performing the following tests:

  • ratio test, current transformer phase angle and polarity measurement
  • testing of low voltage circuit breakers with primary current
  • current protection tests of low voltage circuit breakers
  • testing of direct mode current protection with primary current
  • testing of primary and secondary electrical equipment within RETOM-11M and RET-3000 current and power operating limits.
 

TECHNICAL SPECIFICATIONS

Input voltage
∼(0...220) V
Input current, max
30 А
Output current
3500 А
Number of turns of the primary winding
200

OPERATING CONDITIONS

Operating temperature range
- 20 ... + 50 °С
Transformer weight with cables and connectors, max
36 kg
Overall dimensions, max.
Ø 240 х 90 mm